Rapidontics Labs Create account
Rapidontics Labs › Articles
Article

STL, PLY, OBJ, DICOM: what the research says on file formats

Reviewed by Dr. Utkarsh Rathore, BDS · UP State Dental Council Reg. 21803 · 23 Nov 2026

Illustration: A calm flat illustration of several translucent layers, one grey and one teal, sliding together into a single aligned stack on a soft cream
AI-generated illustration

Short answer

The studies we reviewed do not compare STL, PLY, OBJ and DICOM, so they cannot name one format as the right one for the lab. What they do show is that many digital cases join CBCT data with surface scan data, and that this join needs care [1][2].

So this article does not rank formats. It sets out what the research says about the data that travels to the lab, and what to settle with your lab before you send a case.

What the sources cover, and what they leave out

None of the six sources we used describes the technical properties of STL, PLY, OBJ or DICOM. They do not say which format holds colour, which is smaller, or which a given CAD package prefers. Any claim of that kind would need a source that tests it.

The sources do speak about "digital file format" and "digital file integration" in general terms. Software lets planning data be combined within a digital file format, and that combined data can then be transferred to the surgical field [3]. That is the part this article can speak to.

Two kinds of data, one plan

Computer-assisted implant planning combines radiographic data from CBCT with surface optical scan data. The surface data includes the patient's intraoral situation and the intended restorative planning [1]. The review describes the result as a "virtual patient" [1].

Virtual articulators go a step further. They bring together intraoral scans, facial scans and CBCT [2]. The review says this streamlines how digital models are acquired and articulated, and that it reduces material handling errors [2].

For a lab, this means a case may not be one file. It may be several datasets that must line up with each other. A dentist who sends only one of them may be sending an incomplete picture.

The join is called registration

Bringing CBCT and surface scans into the same space is called registration. One review describes three ways to do it [1]:

The same review says the choice depends on the individual clinical situation [1]. It also notes that scattering artifacts in CBCT scans are an inherent challenge [1]. Two approaches are proposed for that problem: chairside-fabricated composite resin markers, or adhesive spot-markers made for use with computed tomography. Both have limitations [1].

A systematic review of automatic registration looked at 22 studies out of 493 identified. Of these, 14 used geometry-based methods, 7 used artificial intelligence, and 1 compared both [4]. The review reports that geometry-based methods need relatively little computing power, while AI methods showed significant improvements in automation and robustness [4]. It also says future research should address unstable registration landmarks and limited dataset diversity [4].

The lab-side point is simple. How the datasets were matched is information the designer may need. A file name alone does not tell them.

Diagram showing CBCT data and surface scan data being joined by registration into one combined model, with three described registration methods below.
Registration brings CBCT and surface scan data into the same space; the review describes three ways to do it [1].

Where errors can enter

A review of guided implant surgery sets out to describe the steps of the workflow that may influence the surgical outcome, and how to reduce process errors [3]. The file handover is one of those steps, because planning is transferred from the digital file to the field [3].

The virtual articulator review is more direct. It lists "potential distortions during digital file integration" as a challenge. It also calls for robust algorithms to improve the accuracy of data superimposition, and says further clinical validation is needed [2].

Neither review says that one file format causes or prevents these problems. The risk they describe sits in combining and aligning data. It does not sit in the format name.

Scan conditions travel with the file

A file carries what the scanner captured. A review of intraoral scanners reported that illuminance and colour temperature affected trueness and precision [5]. That is a reason to note scanning conditions when you send a case.

The same review reported that repeatability suggested fixed prostheses could be produced within the range of partially edentulous cases. It considered intraoral scanners difficult to use for cross-arch fixed prostheses [5]. It also said that mouth guards and dentures made from intraoral scans may be equivalent to those made from desktop scans [5]. The scope of the case matters as much as the file.

Shade is a separate matter. A systematic review of 17 articles found that intraoral scanners show acceptable precision but unacceptable accuracy for shade matching [6]. Ten articles reported low shade matching accuracy [6]. If shade matters in a case, the studies suggest a scan file alone may not settle it. That is a point to raise with the lab.

A note on digital cases

Rapidontics Labs takes digital cases. Whatever lab you use, the questions below are worth asking first.

Checklist before you send a digital case

Checklist of nine things to settle or include before sending a digital case to a lab.
Checklist before sending a digital case.

Frequently asked questions

Which is better for a dental lab: STL, PLY, OBJ or DICOM?

The sources we reviewed do not compare these formats, so we cannot rank them. They show that cases often combine CBCT and surface scan data, and that distortions can occur during digital file integration [1][2]. Ask your lab which file types its software accepts.

Does a CBCT scan alone give the lab enough information?

Computer-assisted implant planning combines CBCT data with surface optical scan data that shows the intraoral situation and the intended restorative planning [1]. Whether one dataset is enough depends on the case, so confirm with the lab.

What is registration, and why does it matter to the lab?

Registration is the matching of CBCT and intraoral scan data into one model. Described methods include radiographic templates with radiopaque markers, the dual scan technique, and direct registration of intraoral scans using anatomical references [1]. Reviews also note that unstable registration landmarks remain a challenge [4].

Can an intraoral scan file settle the shade?

A systematic review of 17 articles concluded that intraoral scanners show acceptable precision but unacceptable accuracy for shade matching [6]. A separate shade record is worth sending.

Sources

  1. Computer-Assisted Implant Planning: A Review of Data Registration Techniques.. The International journal of periodontics & restorative dentistry, 2025. https://doi.org/10.11607/prd.7127
  2. Advances in Digital Technologies in Dental Medicine: Enhancing Precision in Virtual Articulators.. Journal of clinical medicine, 2025. https://doi.org/10.1016/j.jds.2022.02.002
  3. Reducing errors in guided implant surgery to optimize treatment outcomes.. Periodontology 2000, 2022. https://doi.org/10.1111/prd.12411
  4. Automatic multimodal registration of cone-beam computed tomography and intraoral scans: a systematic review and meta-analysis.. Clinical oral investigations, 2025. https://doi.org/10.1007/s00784-025-06183-x
  5. Accuracy and practicality of intraoral scanner in dentistry: A literature review.. Journal of prosthodontic research, 2020. https://doi.org/10.1016/j.jpor.2019.07.010
  6. Accuracy and precision of intraoral scanners for shade matching: A systematic review.. The Journal of prosthetic dentistry, 2024. https://doi.org/10.1016/j.prosdent.2022.08.034

This article was drafted with AI assistance from the sources listed above and reviewed by Dr. Utkarsh Rathore on 23 Nov 2026. It describes laboratory and digital workflows; clinical decisions stay with the treating dentist.